The InverLux Series is a specialized range of chillers featuring a choice of Two inverter compressors and two on off Scroll compressors, axial fans, and Plate evaporator or shell&tube evaporator. These units are designed to reduce electricity consumption by 15% to 28%, providing significant environmental benefits. Additionally, the series comes equipped with a water pump, making it compatible with water-glycol mixtures, and a storage tank that ensures precise temperature control even when process thermal loads fluctuate. With a cooling capacities ofup to 327.3 kW, the InverLux Series is versatile enough to meet a broad range of customer needs.
Cooling Capacity: 138.74 kW – 327.3 kW
Refrigerant: R-410A
Compressor: Two scroll inverter compressors&Two on off Scroll compressors
Cooling Type: Air-cooled
Applications: Industrial cooling, process cooling, HVAC systems
Air-cooled chillers are cooling devices that transfer heat to the ambient air, typically used in commercial and industrial applications. They cool water by transferring heat to the air and are used in air conditioning systems, industrial processes, and various other applications.
Air-cooled chillers cool water using a refrigerant. The cooling process involves a cycle where the evaporator cools the water and the condenser transfers heat to the air. Fans dissipate heat into the ambient air, cooling the system.
Easier installation and lower cost.
No need for a water source as it does not consume water.
Requires less maintenance due to no issues with water treatment and pipelines.
Saves indoor space as it can be used outdoors.
Efficiency depends on outdoor temperature; performance may decrease in hot weather.
Higher noise levels due to continuous fan operation.
Cooling capacity is generally lower compared to water-cooled chillers.
Regular cleaning of fans and condensers is necessary.
Filters should be checked and replaced frequently.
Refrigerant levels and system pressures should be regularly monitored.
Electrical connections and motors need regular inspections.
Air conditioning systems in commercial buildings.
Industrial process cooling.
Data centers.
Hospitals and laboratories.
Food and beverage industry.
Plastic injection facilities.
Extruder plants.
Metal and steel processing facilities.
Cooling capacity and energy efficiency.
Environmental conditions of the installation site (temperature, humidity, etc.).
Maintenance and service convenience.
Noise levels.
Initial investment cost and operating costs.