Chiller Maintenance And Repair Service

MENU CLOSE

Chiller Maintenance And Repair

CHILLER MAINTENANCE AND REPAIR SERVICE

Importance of Maintenance for Chiller

First functioning and maintenance of Chiller devices should be carried out at the beginning of the season and end of their functioning should be at the end of the season by the expert. Therefore, you will guarantee unproblematic functioning for the first functioning.

Importance of Periodic Maintenance for Chiller

  • Extends the life of the device
  • Reduces the risk of malfunction of the chiller system
  • Reduces energy consumption of the chiller
  • Reduces chiller repair costs
  • Reduces refrigerant gas leaks.

Maintenance which you will provide for your refrigerating device enables your device’s life to be prolonged. When it is applied two times in a year regularly, it will be a measure to prevent the malfunction of your devices. Periodic maintenance should be provided for your device to function properly.
Its performance decreases.
Energy consumption increases by 30%.
Its lifetime decreases because its compressor will not be able to function properly. It causes cost increase in a short-run.

Chiller Maintenance And Repair

Things to Do During Chiller Maintenance

 
  • Supply Voltage Control
  • Control Voltage Control
  • Removing and Cleaning the Contacts
  • Fuse And Contactor Control
  • Control of Thermal Relays
  • Cable Lugs Tightness Check
  • Energy Cables Isolation Control
  • Elect.Card Solvent Cleaning
  • Compressor Voltage Value Measurement
  • Compressor Ampere Value Measurement
  • Compressor Suction Pressure Measurement
  • Compressor Discharge Pressure Measurement
  • Compressor Thermal Control
  • Crankcase Heater Control
  • Resistance Measurement Between Windings
  • Superheat Value Measurement
  • Compressor Temperature Control
  • Crankcase oil acid test
  • Oil level control
  • Seal Checks
  • Visual Leak and Lubrication Check
  • Leak Control with Foam
  • Gas Charging
  • Valve Leak Control
  • Threaded Connection Torque Control
  • Functional Control of Valves
  • General Mechanical Control
  • System Suction Pressure Measurement
  • System Discharge Pressure Measurement
  • Check of Connection Wedges
  • Water pressure control
  • Coolant Exchanger Control
  • Condenser Control
  • Condenser Chemical Cleaning
  • Cond.Fan Voltage Measurement
  • Cond Fan Amperage Measurement
  • Condenser Fan Bearing control
  • Condenser Fan Bearings Replacement
  • Sight Glass Humidity Control
  • Drayer Control
  • Drayer Change
  • Solenoid Valve Function Check
  • Control Unit Control
  • Low Pressure Prosestad Control
  • High Pressure Processade Control
  • Business Thermostat Control
  • Measurement Sensors Control
  • Control of Breaker Circuits
Things to Do During Chiller Maintenance

Aref Experience

We continue to take firm steps in the sector by providing fast, safe and uninterrupted service quality to the needs of our customers in the field of chiller cooling.

Superior Technology

Our company follows technology closely and produce more efficient devices which will decrease the energy consumption for our customers. Equipment used in Chiller devices comply with European standards and provide high efficiency.

Widespread Service Network

We are always there for you with the broad Chiller technical service network all around Turkey. We guarantee to you 2 hours service within Istanbul; 4 hours for out of Istanbul.

A+ Material Quality

AREF SOĞUTMA SİSTEMLERİ which provide customer satisfaction with its domestic and foreign products and services has EN ISO 9001: 2008 and CE certificates.

THOSE WHO PREFER US

Turkish TechnicSiemensÖzgülmak Plastik Makinaları Ltd.Sistem AlüminyumRenova
Jütesan AlüminyumAdaplasmakModern Ambalaj